FLOWGUARD LSZH 6X12 SM-D SP1905 BK

Description

Description

Standards

EN 50200; EN 50399; IEC 60332-1; IEC 60332-3; IEC 60754-2; IEC 60794; IEC 61034

Multi micro-modules cable with dielectric FRP armour:

 

This FLOWGUARD™ (ref. SP1905) is designed for indoor/outdoor installation in railways/tunnel infrastructure or public buildings when circuit integrity during fire is a key point.

The FRP armour provides a high rodent protection. This cable has an  outstanding fire behaviour.

This cable can be operated under a wide temperature range.

FLOWGUARD™ is fire resistant (circuit integrity) following EN50200 during 120minutes.

 

Waterproof dry core structure.

 

Design

The FLOWGUARD™ LSZH*  cable has a central strength member (FRP : Fibre Reinforced Plastic), with bundles around. The design is reinforced by a first layer of aramid yarns, a LSZH* inner sheath, a FRP composed armour and a LSZH* outer steath.

A ripcord is placed beneath the inner and outer sheath for an easy access to the micro-modules.

 

Technical performances

The cable performances are specified in the following tables.

 

Additional details

This cable is provided as a standard with a black sheath and FOTAG bundle color coding.

 

Euroclass

B2ca s1a d1 a1

 

Marking

Aginode FLOWGUARD FIBRE OPTIC CABLE LSZH - SP1905 - XXxYY - TN - metric

XX = Fibre Count YY = Fibre Type  TN = Traceability Number

Characteristics

Characteristics

Construction characteristics
Additional strength member
Aramide
Armour type
FRP
Colour
Black
Construction type
Multibundle
Fiber optic type
SM
Halogen free
IEC 60754-1
Material used for longitudinal water tightness
Swellable yarn
Metal free
Yes
Outer sheath
LSZH
Strength member
Central FRP
Dimensional characteristics
Approximate weight
200 kg/km
Nominal outer diameter (mm)
12.4 mm
Number of optical fibres
72
Number of tubes
6
Mechanical characteristics
Crush resistance (IEC 60794-1-E3)
300 N/cm
Maximum installation tension
5000 N
Mechanical resistance to impacts
10 impacts of 3 N.m
Transmission characteristics
Attenuation, max. 1310 nm (cabled)
0.36 dB/1000m
Attenuation, max. 1550 nm (cabled)
0.23 dB/1000m
Usage characteristics
Bending factor when laying
20 (xD)
Fire resistant
UNE-EN50200 PH120
Fire retardant
IEC 60332-3
Flame retardant
IEC 60332-1
Installation temperature, range
-5...40 °C
Installation type
Indoor/Outdoor
Minimum static operating bending radius
200 mm
Operating temperature, range
-40...70 °C
Rodent protection
FRP
Smoke density
IEC 61034-2
Storage temperature, range
-40...70 °C

Products

FLOWGUARD FOTAG 24

FLOWGUARD LSZH 2X12 SM-D SP1905 BK

Aginode ref. 10563593

  • Colour: Black
  • Number of optical fibres: 24
  • Number of tubes: 2

 

FLOWGUARD FOTAG 48

FLOWGUARD LSZH 4X12 SM-D SP1905 BK

Aginode ref. 10565775

  • Colour: Black
  • Number of optical fibres: 48
  • Number of tubes: 4