LANmark-OF Plug&Play Low Loss Module Female Universal 12 LC SM Blue

Description

Description

The Plug&Play system consists of 3 subcomponents: the Plug&Play modules, the MPO-MPO Pre-Terms and the Plug&Play patch panel.

The central component is the pre-installed Plug&Play module. The MPO connector at the back of the module connects at once 12 fibres to the MPO-MPO Pre-Term. Inside the module the fibres are spread out towards the LC adaptors at the front.

Up to 4 Plug&Play modules can be installed quickly into the Plug&Play patch panel with push rivets. With these 4 modules a medium density of 48 LC or a high density of 96 LC connections within 1U can be achieved.

The insertion loss for the Plug&Play module is measured according to standard IEC 61300-3-45. The minimum return loss for a MPO connection is measured according to IEC 61300-3-6.

The module's default polarity is universal, Type U1 according to TIA-568.3-E. Other polarities like Type A, Type B and Type C can be customized upon request.

For polarity methods A,B ,C ,U1of standard TIA 568.3-E following modules and trunks need to be used:

  • For a polarity method A implementation with a Type A Pre-Term and straight modules are used on both sides of the link.
  • For a polarity method B implementation with a Type B Pre-Term and a straight cassette is used on one side of the link and a crossed module on the other side of the link.
  • For a polarity method C implementation with a Type C Pre-Term and straight modules are used on both sides of the link.
  • For a polarity method U1 implementation with a Type B Pre-Term and universal modules are used on both sides of the link.

Since all connectivity is factory terminated and tested installation times are short facilitating a quick deployment.

Characteristics

Characteristics

Construction characteristics
Connector type
LC
Fiber optic type
SingleMode 9/125
Wiring type
Polarity Universal
Dimensional characteristics
Number of optical fibres
12
Transmission characteristics
Insertion Loss, maximum, dB
0.75 dB
Insertion loss, typical value
0.5 dB
Return Loss, Minimum, dB
45 dB