Aller au contenu principal

Aerial and duct cable 5.0mm - PIA

Aerial and duct cable 5.0mm - PIA

Description

Description

Normes

IEC 60794; IEC 60793

This cable is designed for outdoor duct and aerial installations. It features a loose tube construction containing 1 fibre, filled with jelly for fibre protection. The cable includes water-blocking materials to prevent moisture ingress. Its outer sheath is made of high-density polyethylene (HDPE) and includes two fibre-reinforced plastic (FRP) elements embedded symmetrically in the sheath for added strength and stability.

 

Breaking load: max 2000N

PIA Approved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test Methods

All optical measurements at 1550 nm

TestConditionsAcceptance criteria
Tension Loading IEC 60794-1-2 E1Tensile strength: 800N and 300N Sample length: ≥50 m, 1 minΔɑ≤0.1dB under 300N and reversible under 800N
Crush/Compression IEC 60794-1-2 E3Crush: 20Kg/cm, 1min
Number of tests: 3, at least 20cm apart.
Δɑ reversible
No damage
Impact
IEC 60794-1-2 E4
Impact energy: 5Nm, R=300mm number of test: 3Δɑ reversible
Torsion
IEC 60794-1-2 E7
1m, ±180°, 10 cyclesΔɑ≤0.1dB
Bending
IEC 60794-1-2 E11
R=10xCable Φ, 4 turn, 3 cyclesΔɑ reversible
Temperature Cycling IEC 60794-1-2 F1-20~+70°C, two cycles, t1=180minΔɑ≤0.1dB
Water penetration IEC 60794-1-2 F5BHeight of water column: 1m Sample length: 3m, 24hNo water leakage

Caractéristiques

Caractéristiques

Caractéristiques de construction
Couleur
Noir
Type de connecteur
Hardened Standard (Corning Optitap compatible)
Dielectric
Yes
Type de fibres optiques
SM (G657.A2)
Gaine extérieure
PE haute densité
Type de câble
Aerial
Caractéristiques dimensionnelles
Masse approximative
20 kg/km
Diamètre du câble
5.0 mm
Nombre de fibres optiques
1
Caractéristiques mécaniques
Breaking strength
Max 2 kN
Résistance à l'écrasement
20 kg/cm
Force de traction maximale
800 N
Caractéristiques de transmission
Insertion Loss, maximum, dB
0.25 dB
Insertion loss, typical value
0.12 dB
Return Loss, Minimum, dB
65 dB
Caractéristiques d'utilisation
Application
Customer connection
Température ambiante d'installation, plage
-5...50 (operation -20...70) °C
Type d'installation
Aerial - self-supporting
Rayon de courbure minimum - installé
R=10D without tension mm
Conditionnement
PCDC packaging

Produits