Aller au contenu principal

Indoor (B2Ca) semi tight buffer

Indoor (B2Ca) semi tight buffer

Description

Description

Normes

IEC 60794; IEC 60793

This cable features a semi-tight buffer construction with a single bare optical fiber, providing a balance between flexibility and protection. It is available with 1, 2 or 4 buffered fibres. It is reinforced with aramid yarns for added tensile strength and covered with a white LSZH (low smoke zero halogen) outer sheath that is UV-stabilized for outdoor or exposed indoor use. The cable meets the high fire performance requirements of CPR Class B2Ca.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test Methods

All optical measurements at 1550 nm 

Test Conditions Acceptance criteria 
Tension Loading IEC 60794-1-21 E1 Tensile strength: 250N 
Sample length: ≥50 m, 1 min 
Δɑ≤0.1dB 
Crush/Compression IEC 60794-1-21 E3 Crush: 15Kg/cm, 1min 
Number of tests: 3, at least 20cm apart. 
After test, Δɑ≤0.05dB 
No damage 
Impact IEC 60794-1-21 E4 Impact energy:1Nm number of test: 3 After test, Δɑ≤0.05dB 
No damage 
Torsion IEC 60794-1-21 E7 2m cable, ±180° After test, Δɑ≤0.05dB 
No damage 
Bending IEC 60794-1-21 E11A 10 turns, 5 cycles, R=10D After test, Δɑ≤0.1dB 
No damage
Temperature cycling IEC 60794-1-22 F1 -5~+60°C, t1=180min, 2 cycles Δɑ≤0.1dB/km

Caractéristiques

Caractéristiques

Caractéristiques de construction
Couleur
Blanc
Type de connecteur
SC/APC LC/APC
Dielectric
Yes
Type de fibres optiques
SM (G657.A2)
Gaine extérieure
Faible dégagement de fumée et sans halogène
Type de câble
Indoor
Caractéristiques dimensionnelles
Masse approximative
6 kg/km
Diamètre du câble
2.8 mm
Nombre de fibres optiques
1...4
Caractéristiques mécaniques
Résistance à l'écrasement
15 kg/cm
Force de traction maximale
Install 250 (service 70) N
Caractéristiques de transmission
Insertion Loss, maximum, dB
0.25 dB
Insertion loss, typical value
0.12 dB
Return Loss, Minimum, dB
65 dB
Caractéristiques d'utilisation
Application
Customer connection
Température ambiante d'installation, plage
-5...60 (operation -5...60) °C
Type d'installation
Intérieur
Rayon de courbure minimum - installé
R=10D without tension mm
Conditionnement
PCDC packaging

Produits