Railways - Multibundle K209 cables

Products

MBC LSZH K209B 4x50/125 OM3 SP1344 BK

Nexans ref. tdb

  • Fiber optic type: OM3 50/125
  • Colour: Black
  • Number of optical fibres: 4
  • Number of tubes: 1
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC LSZH K209B 6xSM G652D SP1344 BK

Nexans ref. 10548533

  • Fiber optic type: SM (G.652D)
  • Colour: Black
  • Number of optical fibres: 6
  • Number of tubes: 1
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC LSZH K209B 6x50/125 OM3 SP1344 BK

Nexans ref. 10507006

  • Fiber optic type: OM3 50/125
  • Colour: Black
  • Number of optical fibres: 6
  • Number of tubes: 1
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC LSZH K209B 2x6 50/125 OM3 SP1344 BK

Nexans ref. 10545733

  • Fiber optic type: OM3 50/125
  • Colour: Black
  • Number of optical fibres: 12
  • Number of tubes: 2
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC LSZH K209B 2x6SM G652D SP1344 BK

Nexans ref. 10145800

  • Fiber optic type: SM (G.652D)
  • Colour: Black
  • Number of optical fibres: 12
  • Number of tubes: 2
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC LSZH K209B 6x6SM G652D SP1344 BK

Nexans ref. 10504788

  • Fiber optic type: SM (G.652D)
  • Colour: Black
  • Number of optical fibres: 36
  • Number of tubes: 6
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC LSZH K209B 4x6SM + 4x6MM SP1400 BK

Nexans ref. 10508928

  • Fiber optic type: -
  • Colour: Black
  • Number of optical fibres: 48
  • Number of tubes: 8
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC LSZH K209B 6x12SM G652D SP1349 BK

Nexans ref. 10513197

  • Fiber optic type: SM (G.652D)
  • Colour: Black
  • Number of optical fibres: 72
  • Number of tubes: 6
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC LSZH K209B 6x12SM G657A2 SP1349 BK

Nexans ref. 14500598

  • Fiber optic type: SM (G657.A2)
  • Colour: Black
  • Number of optical fibres: 72
  • Number of tubes: 6
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC K209c LSZH 8x12SM G652D SP1757 BK

Nexans ref. 10508458

  • Fiber optic type: SM (G.652D)
  • Colour: Black
  • Number of optical fibres: 96
  • Number of tubes: 8
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC K209 LSZH 12x12SM G652D SP1758 BK

Nexans ref. 10509235

  • Fiber optic type: SM (G.652D)
  • Colour: Black
  • Number of optical fibres: 144
  • Number of tubes: 12
  • Crush resistance (IEC 60794-1-E3): 300 N/cm
  • Mechanical resistance to impacts: 10 impacts of 1 N.m
  • Operating temperature, range: -20 ... 60 °C
  • Installation temperature, range: -20 ... 60 °C

 

MBC K209B LSZH 24x6SM SP1921 BK

Nexans ref.

  • Fiber optic type: SM
  • Colour: Black
  • Number of optical fibres: 144
  • Number of tubes: 24
  • Crush resistance (IEC 60794-1-E3): 200 N/cm
  • Mechanical resistance to impacts: 3 impacts of 5 N.m
  • Operating temperature, range: -30 ... 60 °C
  • Installation temperature, range: -5 ... 60 °C

 

MBC K209B LSZH 24x12SM G657A1 SP1921 BK

Nexans ref. 10562651

  • Fiber optic type: SM (G.652D)
  • Colour: Black
  • Number of optical fibres: 288
  • Number of tubes: 24
  • Crush resistance (IEC 60794-1-E3): 200 N/cm
  • Mechanical resistance to impacts: 3 impacts of 5 N.m
  • Operating temperature, range: -30 ... 60 °C
  • Installation temperature, range: -5 ... 60 °C

 

MBC K209B LSZH 24x12SM G657A2 SP1921 GY

Nexans ref. 14500004

  • Fiber optic type: SM (G657.A2)
  • Colour: Grey
  • Number of optical fibres: 288
  • Number of tubes: 24
  • Crush resistance (IEC 60794-1-E3): 200 N/cm
  • Mechanical resistance to impacts: 3 impacts of 5 N.m
  • Operating temperature, range: -30 ... 60 °C
  • Installation temperature, range: -5 ... 60 °C

 

Description

Description

Standards

  • International
    EN 50399 B2; IEC 60331-2; IEC 60332-1; IEC 60332-3; IEC 60754-1; IEC 60794; IEC 61034
  • National
    NF C32-070/C1

Multi Micro-bundles cable with corrugated steel armour:

 

SP1344 - up to 36 fibres modulo 6

SP1400 - up to 48 fibres modulo 6

SP1349 - up to 72 fibres modulo 12

SP1757 - up to 96 fibres modulo 12

SP1758 - up to 144 fibres modulo 12

SP1921 - up to 288 fibres modulo 12

 

This multi micro-bundles cable is designed for indoor/outdoor installation in railways infrastructure.

The  corrugated steel armour provides a high rodent protection. This cable has an  outstanding fire behaviour.

Access to µbundles is made easy with the internal ripcord.

This cable can be operated under a large temperature range.

 

Design

The MBC LSZH*  cable has a central strength member (FRP : Fibre Reinforced Plastic), with bundles (maximum 6 fibres per bundle) around. The design is reinforced by a first layer of watertight glass, a LSZH* inner sheath, a second layer of watertight glass yarns, a corrugated steel armour and a LSZH* outer steath.

 

Fibre type

The MBC LSZH* cable is available with singlemode and multimode fibres.

 

Technical performances

The multibundle cable performances are specified in the following tables.

 

Additional details

This cable is provided as a standard with a black sheath, other sheath colours are also available. Long exposure to UV with these other colours could generate colour fading.

The sheathing material is compliant with ISO 4892-2 regarding the UV exposure.

The cable is compliant with NFPA - IEEE1202 &UL1685.

 

Euroclass

B2ca S1a a1 d0

 

* LSZH: Low Smoke Zero Halogen.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Strength member
Central FRP
Construction type
Multibundle
Additional strength member
Glass yarn
Armour type
Corrugated steel
Outer sheath
LSZH
Halogen free
IEC 60754-1
Metal free
No

Usage characteristics

Usage characteristics

Fire resistant
NF C 32-070 CR1
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Smoke density
IEC 61034-2
U.V resistance
Good
Rodent protection
Corrugated steel tape
Water proof
Longitudinal & radial
Installation type
Indoor/Outdoor

Resources

Resources

Selling & delivery Information

Standard Marking

Aginode - FIBRE OPTIC CABLE - MBC LSZH SPxxxx - XXxYY - FB - TN - metric

XX = Fibre Count YY = Fibre Type FB = Frameries, Belgium (manufacturing place) TN = Traceability Number

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close