LANmark-OF UC Outdoor PE 2-24core APAC Region

Products

LANmark-OF UC PE 12core OM3 Black APAC Region

Nexans ref. N175.185

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 12
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 12core OM4 Black APAC Region

Nexans ref. N177.185

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 12
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 12core SM G.652.D Black APAC Region

Nexans ref. N174.185

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 12
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4):
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 24core OM3 Black APAC Region

Nexans ref. N175.191

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 24
  • Outer Diameter: 9.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 184.0 mm
  • Minimum static operating bending radius: 92 mm

 

LANmark-OF UC PE 24core OM4 Black APAC Region

Nexans ref. N177.191

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 24
  • Outer Diameter: 9.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 184.0 mm
  • Minimum static operating bending radius: 92 mm

 

LANmark-OF UC PE 24core SM G.652.D Black APAC Region

Nexans ref. N174.191

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 24
  • Outer Diameter: 9.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 184.0 mm
  • Minimum static operating bending radius: 92 mm

 

LANmark-OF UC PE 2core OM3 Black APAC Region

Nexans ref. N175.180

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 2
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 2core OM4 Black APAC Region

Nexans ref. N177.180

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 2
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 2core SM G.652.D Black APAC Region

Nexans ref. N174.180

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 2
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 4core OM3 Black APAC Region

Nexans ref. N175.181

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 4
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 4core OM4 Black APAC Region

Nexans ref. N177.181

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 4
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 4core SM G.652.D Black APAC Region

Nexans ref. N174.181

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 4
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 6core OM3 Black APAC Region

Nexans ref. N175.182

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 6
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 6core OM4 Black APAC Region

Nexans ref. N177.182

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 6
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 6core SM G.652.D Black APAC Region

Nexans ref. N174.182

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 6
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 8core OM3 Black APAC Region

Nexans ref. N175.183

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 8
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 8core OM4 Black APAC Region

Nexans ref. N177.183

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 8
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 8core SM G.652.D Black APAC Region

Nexans ref. N174.183

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 8
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

Description

Description

Standards

  • International
    IEC 60793-2-10; ISO/IEC 11801
  • National
    ANSI/TIA-568-C.3

Description and Application
 

Aginode LANmark-OF UC fibre cable is designed for outdoor applications. The construction is suitable for use outdoor for direct burial. It consists of a Unitube structure protected by corrugated steel tape armouring, the Unitube can hold up to 24C fibres. This provides rodent protection and high crush resistance. The cable has a HDPE outer jacket.

Construction
  
Legend accompanying the cross section drawing:

  1. Optical fibres (250 um)
  2. Waterproof gel filling
  3. Loose tube
  4. Glass Yarn
  5. Corrugated steel tape armour
  6. HDPE outer jacket with UV resistant additive 

Characteristics

  • Designed for termination by splicing
  • Central loose tube design
  • Corrugated steel protection
  • Waterproof structure and UV-resistant
  • Available in Multimode and Singlemode fibre
  • Available from 2-24 fibres

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Galvanized steel tapes
Outer sheath
HDPE
Sheath colour
Black

Mechanical characteristics

Mechanical characteristics

Crush resistance (IEC 60794-1-E3)
300 N/cm
Maximum pulling force (IEC 60794-1-2-E1)
1300 N

Usage characteristics

Usage characteristics

Ambient installation temperature, range
0 ... 40 °C
Operating temperature, range
-20 ... 60 °C
Storage temperature, range
-30 ... 60 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close