LANmark-OF UC Outdoor LSZH 2-24core APAC Region

Products

LANmark-OF UC LSZH 12core OM3 Black

Nexans ref. N175.475

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 12
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 12core OM4 Black

Nexans ref. N177.475

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 12
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 12core OM5 Black

Nexans ref. N179.475

  • Packaging: m (1000m)
  • Fiber optic type: OM5 50/125 Wideband
  • Number of optical fibres: 12
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 12core SM G.652.D Black

Nexans ref. N174.475

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 12
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 24core OM3 Black

Nexans ref. N175.481

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 24
  • Outer Diameter: 10.6 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 212.0 mm
  • Minimum static operating bending radius: 106 mm

 

LANmark-OF UC LSZH 24core OM4 Black

Nexans ref. N177.481

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 24
  • Outer Diameter: 10.6 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 212.0 mm
  • Minimum static operating bending radius: 106 mm

 

LANmark-OF UC LSZH 24core OM5 Black

Nexans ref. N179.481

  • Packaging: m (1000m)
  • Fiber optic type: OM5 50/125 Wideband
  • Number of optical fibres: 24
  • Outer Diameter: 10.6 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 212.0 mm
  • Minimum static operating bending radius: 106 mm

 

LANmark-OF UC LSZH 24core SM G.652.D Black

Nexans ref. N174.481

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 24
  • Outer Diameter: 10.6 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 212.0 mm
  • Minimum static operating bending radius: 106 mm

 

LANmark-OF UC LSZH 2core OM3 Black

Nexans ref. N175.470

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 2
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 2core OM4 Black

Nexans ref. N177.470

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 2
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 2core OM5 Black

Nexans ref. N179.470

  • Packaging: m (1000m)
  • Fiber optic type: OM5 50/125 Wideband
  • Number of optical fibres: 2
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 2core SM G.652.D Black

Nexans ref. N174.470

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 2
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 4core OM3 Black

Nexans ref. N175.471

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 4
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 4core OM4 Black

Nexans ref. N177.471

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 4
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 4core OM5 Black

Nexans ref. N179.471

  • Packaging: m (1000m)
  • Fiber optic type: OM5 50/125 Wideband
  • Number of optical fibres: 4
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 4core SM G.652.D Black

Nexans ref. N174.471

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 4
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 6core OM3 Black

Nexans ref. N175.472

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 6
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 1000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 6core OM4 Black

Nexans ref. N177.472

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 6
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 6core OM5 Black

Nexans ref. N179.472

  • Packaging: m (1000m)
  • Fiber optic type: OM5 50/125 Wideband
  • Number of optical fibres: 6
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 6core SM G.652.D Black

Nexans ref. N174.472

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 6
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 8core OM3 Black

Nexans ref. N175.473

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 8
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 8core OM4 Black

Nexans ref. N177.473

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 8
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 8core OM5 Black

Nexans ref. N179.473

  • Packaging: m (1000m)
  • Fiber optic type: OM5 50/125 Wideband
  • Number of optical fibres: 8
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 8core SM G.652.D Black

Nexans ref. N174.473

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 8
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60332-3 Cat.C; IEC 60793-2-10; ISO/IEC 11801
  • National
    ANSI/TIA-568.3-D

Description and Application
 

Aginode LANmark-OF UC fibre cable is designed for outdoor applications. The construction is suitable for use outdoor for direct burial. It consists of a Unitube structure protected by corrugated steel tape armouring, the Unitube can hold up to 24C fibres. This provides rodent protection and high crush resistance. The cable has a LSZH outer jacket.

Construction
  
Legend accompanying the cross section drawing:

  1. Optical fibres (250 um)
  2. Waterproof gel filling
  3. Loose tube
  4. Glass Yarn
  5. Corrugated steel tape armour
  6. LSZH outer jacket with UV resistant additive 

 
Characteristics
 

  • Flame retardant (IEC 60332-1) and fire retardant (IEC 60332-3-24)
  • Designed for termination by splicing
  • Central loose tube design
  • Corrugated steel protection
  • Waterproof structure and UV-resistant
  • Available in Multimode and Singlemode fibre
  • Available from 2-24 fibres

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Corrugated steel
Outer sheath
LSZH
Sheath colour
Black

Mechanical characteristics

Mechanical characteristics

Maximum pulling force (IEC 60794-1-2-E1)
1300 N

Usage characteristics

Usage characteristics

Ambient installation temperature, range
0 ... 40 °C
操作温度范围
-20 ... 60 °C
Storage temperature, range
-30 ... 60 °C

Resources

Resources

Documentation

xlsx — 0 B
xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close