LANmark-OF ENSPACE 方法 B MTP-MTP预端接光缆 LSZH
LANmark-OF ENSPACE 方法 B MTP-MTP预端接光缆 LSZH
- 工厂端接 MTP-MTP 光纤组件
- 灵活的扇出设计便于在配线架中安装
- 电缆直径小,减少了数据中心所需空间
- 方法 B 极性预端接,可配合通用极性卡盒
- 针对 100G/400G 并行传输进行了优化
- 光纤数量12F、24F、48F、96F
- 光纤类型OM3、OM4、OM5 和单模(OS2 G.657.A1)
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term SM 12c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Aginode ref. N144.B12MMExxxY
- 光纤类型: SM (G657.A1)
- 光纤数: 12
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM5 Lime Green
Aginode ref. N149.B48MMExxxL
- 光纤类型: OM5 50/125
- 光纤数: 48
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM5 Lime Green
Aginode ref. N149.B24MMExxxL
- 光纤类型: OM5 50/125
- 光纤数: 24
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM3 Aqua
Aginode ref. N145.B24MMExxxA
- 光纤类型: OM3 50/125
- 光纤数: 24
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM5 Lime Green
Aginode ref. N149.B12MMExxxL
- 光纤类型: OM5 50/125
- 光纤数: 12
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM4 Aqua
Aginode ref. N147.B96MMExxxA
- 光纤类型: OM4 50/125
- 光纤数: 96
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM4 Aqua
Aginode ref. N147.B48MMExxxA
- 光纤类型: OM4 50/125
- 光纤数: 48
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM4 Aqua
Aginode ref. N147.B24MMExxxA
- 光纤类型: OM4 50/125
- 光纤数: 24
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM3 Aqua
Aginode ref. N145.B12MMExxxA
- 光纤类型: OM3 50/125
- 光纤数: 12
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM4 Aqua
Aginode ref. N147.B12MMExxxA
- 光纤类型: OM4 50/125
- 光纤数: 12
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term SM 96c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Aginode ref. N144.B96MMExxxY
- 光纤类型: SM (G657.A1)
- 光纤数: 96
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM3 Aqua
Aginode ref. N145.B96MMExxxA
- 光纤类型: OM3 50/125
- 光纤数: 96
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term SM 48c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Aginode ref. N144.B48MMExxxY
- 光纤类型: SM (G657.A1)
- 光纤数: 48
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM3 Aqua
Aginode ref. N145.B48MMExxxA
- 光纤类型: OM3 50/125
- 光纤数: 48
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term SM 24c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Aginode ref. N144.B24MMExxxY
- 光纤类型: SM (G657.A1)
- 光纤数: 24
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM5 Lime Green
Aginode ref. N149.B96MMExxxL
- 光纤类型: OM5 50/125
- 光纤数: 96
Description
Description
Standards
基于 Micro-Bundle Universal 的数据中心、楼宇和园区预端接光缆
电缆直径小,弯曲半径大,可满足数据中心的要求。
防火性能
电缆已根据 IEC 60332-3c 进行了防火性能测试。电缆符合 LSZH 要求。
MTP*-MTP 预端接特性
MTP-MTP Pre-Term 带有标准插针(公头)连接器。这与 ENSPACE 模块和 Plug&Play 模块中的无针脚(母头)连接器相匹配。
为了减少数据中心的过长现象,预端线是定制的,增量为 1 米。N 编号中的 "xxx "是电缆接头之间的长度(以米为单位),即配线架背面之间的预接线长度。
预接线经过优化,适用于数据中心的拉线和敷设。MTP 连接器的两侧都有泡沫保护。拉环的最大拉力为 450N。带波纹管的可拆卸拉环可通过 PN N890.100HP 订购。
MTP-MTP 预端子配有 PG-13 电缆压盖
光学性能和极性
多模 MTP-MTP* 连接的插入损耗具有低损耗性能:典型插入损耗为 0.15 dB,最大插入损耗为 0.35 dB。还可提供超低损耗,典型插入损耗为 0.125dB,最大插入损耗为 0.25dB。
单模 MTP-MTP* 连接的插入损耗具有低损耗性能:典型插入损耗为 0.3dB,最大插入损耗为 0.35dB。
MTP-MTP* 连接的插入损耗是根据 IEC61300-3-45 标准测量的。
多模 MTP 连接的最小回波损耗为 20 dB,测量依据是 IEC 61300-3-6。根据 IEC 61300-3-6 测量,单模 MTP 连接的最小回波损耗为 45 dB。
方法 B 预端子具有键上/键上设计。可配合通用极性卡盒,使链路两端可采用同一种卡盒类型满足双工LC传输需求。