LANmark-OF MTP-MTP Patch Cords

Products

LANmark-OF Patch Cord Female MTP PRO - Female MTP PRO OM4 LSZH xm Aqua

Nexans ref. N125.7GGAx

  • 光纤类型: OM4 50/125
  • 颜色: 水绿

 

LANmark-OF Patch Cord Female MTP PRO - Female MTP PRO SM LSZH xm Yellow

Nexans ref. N125.4GGYx

  • 光纤类型: 单模9/125
  • 颜色:

 

LANmark-OF Patch Cord Female MTP Pro - Female MTP Pro OM4 LSZH xm Violet

Nexans ref. N125.7GGVx

  • 光纤类型: OM4 50/125
  • 颜色: 蓝紫

 

Description

Description

Standards

  • International
    ISO/IEC 11801

DESCRIPTION

Aginode LANmark-OF MTP-MTP patch cords have been designed for indoor applications in support of parallel optics, i.e. 40GBase-SR4 and 100GBase-SR4.

Details on the supported distances can be found in the LANmark-OF warranty modules.

 

Typical installation environments are data centres:

  • Connections from patch panels to the active equipment
  • Cross connects

 

Aginode LANmark-OF MTP patch cords are delivered as straight patch cords with a key up - key up design, i.e. the method B polarity.  The patch cords are delivered with female MTP* PRO connectors.

 

For ease of patching the MTP PRO connector has a short boot length of 17mm.

 

With the tool in the LANmark-OF Tool MTP PRO Sample Box (N890.160) the gendre and polarity of the patch cords can be changed

  • Gendre can be changed to male with the pins of product N890.161
  • The polarity can be changed to a key up – key down design.

 

The patch cords are available with LANmark-OF OM4 performance.   Details on the fibre specifications can be found in the detailed fibre datasheets.

 

The typical value for the insertion loss for a multimode MTP connection is 0,125 dB. The limit value for a multimode MTP connection is 0,25 dB measured according to standard IEC 61300-3-45. The minimum return loss for a multimode MTP connection is 20 dB measured according to IEC 61300-3-6.

 

Mechanical characteristics of the Pre-Term are conform to the IEC 60794-20 standard for indoor cables. The small diameter of 2.5 mm and the small bend radius of 30mm the cable facilitates the patching in densely populated areas in the data centre.

 

The length between the 2 MTP-connectors is variable and can be increased in steps of 1m.  The "X" in the N-number equals Xm.

 

* MTP is a trade name of US Conec

Characteristics

Characteristics

结构特性

结构特性

外护套
低烟无卤阻燃

机械特性

机械特性

抗冲击性能(IEC 60794-1-E4)
10次冲击/ N.M
耐挤压 (IEC 794-1-E3)
50 N/cm

Resources

Resources

联系我们

您需要获得更多信息的话题

必填字段*

请检查您的输入重新尝试

所有的邮箱地址必须包含一个单独的@

个人数据保护

您有权反对将您的个人数据和/或将其用于直接营销或商业目的

谢谢

感谢垂询。我们将尽快和您联系。

错误

发生错误。请重试。

关闭