LANmark-OF UC Outdoor PE 48-96core APAC Region

Products

LANmark-OF UC Outdoor HDPE 48 core OM3 50/125

Nexans ref. N175.203

  • 光纤类型: OM3 50/125
  • 光纤数: 48
  • 外径: 10.8 mm
  • 最大拉力(IEC 60794-1-2-E1): 1500 N
  • 最小弯曲半径 - 动态: 216.0 mm
  • 最小弯曲半径 - 静态: 108 mm

 

LANmark-OF UC Outdoor HDPE 48 core OM4 50/125

Nexans ref. N177.203

  • 光纤类型: OM4 50/125
  • 光纤数: 48
  • 外径: 10.8 mm
  • 最大拉力(IEC 60794-1-2-E1): 1500 N
  • 最小弯曲半径 - 动态: 216.0 mm
  • 最小弯曲半径 - 静态: 108 mm

 

LANmark-OF UC Outdoor HDPE 48 core SM 9/125 G.652.D

Nexans ref. N174.203

  • 光纤类型: SM (G.652D)
  • 光纤数: 48
  • 外径: 10.8 mm
  • 最大拉力(IEC 60794-1-2-E1): 1500 N
  • 最小弯曲半径 - 动态: 216.0 mm
  • 最小弯曲半径 - 静态: 108 mm

 

LANmark-OF UC Outdoor HDPE 72 core OM3 50/125

Nexans ref. N175.215

  • 光纤类型: OM3 50/125
  • 光纤数: 72
  • 外径: 11.6 mm
  • 最大拉力(IEC 60794-1-2-E1): 3000 N
  • 最小弯曲半径 - 动态: 232.0 mm
  • 最小弯曲半径 - 静态: 116 mm

 

LANmark-OF UC Outdoor HDPE 72 core OM4 50/125

Nexans ref. N177.215

  • 光纤类型: OM4 50/125
  • 光纤数: 72
  • 外径: 11.6 mm
  • 最大拉力(IEC 60794-1-2-E1): 3000 N
  • 最小弯曲半径 - 动态: 232.0 mm
  • 最小弯曲半径 - 静态: 116 mm

 

LANmark-OF UC Outdoor HDPE 72 core SM 9/125 G.652.D

Nexans ref. N174.215

  • 光纤类型: SM (G.652D)
  • 光纤数: 72
  • 外径: 11.6 mm
  • 最大拉力(IEC 60794-1-2-E1): 3000 N
  • 最小弯曲半径 - 动态: 232.0 mm
  • 最小弯曲半径 - 静态: 116 mm

 

LANmark-OF UC Outdoor HDPE 96 core OM3 50/125

Nexans ref. N175.227

  • 光纤类型: OM3 50/125
  • 光纤数: 96
  • 外径: 13.2 mm
  • 最大拉力(IEC 60794-1-2-E1): 3000 N
  • 最小弯曲半径 - 动态: 264.0 mm
  • 最小弯曲半径 - 静态: 132 mm

 

LANmark-OF UC Outdoor HDPE 96 core OM4 50/125

Nexans ref. N177.227

  • 光纤类型: OM4 50/125
  • 光纤数: 96
  • 外径: 13.2 mm
  • 最大拉力(IEC 60794-1-2-E1): 3000 N
  • 最小弯曲半径 - 动态: 264.0 mm
  • 最小弯曲半径 - 静态: 132 mm

 

LANmark-OF UC Outdoor HDPE 96 core SM 9/125 G.652.D

Nexans ref. N174.227

  • 光纤类型: SM (G.652D)
  • 光纤数: 96
  • 外径: 13.2 mm
  • 最大拉力(IEC 60794-1-2-E1): 3000 N
  • 最小弯曲半径 - 动态: 264.0 mm
  • 最小弯曲半径 - 静态: 132 mm

 

Description

Description

Standards

  • International
    IEC 60793-2-10; ISO/IEC 11801
  • National
    ANSI/TIA-568-C.3

Description and Application
 

Aginode LANmark-OF UC fibre cable is designed for outdoor applications. The construction is suitable for use outdoor for direct burial. It consists of a central strength member surrounded by multiple loose tubes. A corrugated steel tape armour protects the sub-tubes. Each loose tube can hold up to 12C fibres and the structure can hold up to 12 sub-tubes. This provides rodent protection and high crush resistance. The cable has a HDPE outer jacket.

Construction
  
Legend accompanying the cross section drawing:

  1. Optical fibres (250 um)
  2. Waterproof gel filling
  3. Loose tube
  4. Glass Yarn
  5. Central Strength Member
  6. Corrugated steel tape armour
  7. HDPE outer jacket with UV resistant additive 

Characteristics

  • Designed for termination by splicing
  • Central loose tube design
  • Corrugated steel protection
  • Waterproof structure and UV-resistant
  • Available in Multimode and Singlemode fibre
  • Available from 48/72/96 fibres

Characteristics

Characteristics

结构特性

结构特性

外护套
HDPE
护套颜色
铠装类型
镀锌钢带

机械特性

机械特性

耐挤压 (IEC 794-1-E3)
300 N/cm
抗冲击性能(IEC 60794-1-E4)
100次冲击/ 3N.M

使用特性

使用特性

环境安装温度,范围
0 ... 40 °C
操作温度,范围
-40 ... 70 °C
存储温度范围
-40 ... 70 °C