メインコンテンツに移動

LANmark-OF UC PE (Unitube Steel Armoring - Outdoor)

商品

0495 UC 2elts

LANmark-OF UC 12x Multimode 50/125 OM3 PE Black

Aginode ref. N165.UCPE12B

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 12

 

0495 UC 2elts

LANmark-OF UC 24x Multimode 50/125 OM3 PE Black

Aginode ref. N165.UCPE24B

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 24

 

0495 UC 2elts

LANmark-OF UC 12x Multimode 50/125 OM4 PE Black

Aginode ref. N167.UCPE12B

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 12

 

0495 UC 2elts

LANmark-OF UC 24x Multimode 50/125 OM4 PE Black

Aginode ref. N167.UCPE24B

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 24

 

0495 UC 2elts

LANmark-OF UC 6x Multimode 50/125 OM4 PE Black

Aginode ref. N167.UCPE06B

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 6

 

説明

説明

Standards

ISO/IEC 11801

Description and Application
 
 The construction is suitable for use outdoor in ducts and for direct burial. It consists of a corrugated steel tape armouring providing full rodent protection. It is surrounded by glass yarns. The cable has a HDPE outer jacket.
The loose tube design has a capacity of up to 24 fibres.  Diameter of the fibres is 250 um.  Termination of these fibres is done with splicing of pigtails.
The cable is watertight due to the gel in the loose tube and the watertight glass yarns.

 
Construction
 
 
Legend accompanying the cross section drawing:

  1. Optical fibres (250 um)
  2. Gel
  3. Loose tube
  4. Reinforced watertight glass yarns 
  5. Corrugated steel tape armour
  6. PE outer jacket with UV resistant additive 

 
Characteristics

  • Outdoor cable for installation in a duct or direct burial
  • Designed for termination by splicing
  • Central loose tube design
  • Corrugated steel protection
  • Waterproof structure, rodent resistant and UV-resistant
  • Available in all fibre grades
  • Available from 4-24 fibres

Characteristics

Characteristics

Construction characteristics
Fiber optic type
OM3 50/125
Dimensional characteristics
Approximate weight
85 kg/km
Number of optical fibres
12
Nominal outer diameter (mm)
8.5 mm
Mechanical characteristics
Mechanical resistance to impacts
3 impacts of 5 N.m
Maximum operating pulling force
450 N
Maximum pulling force (IEC 60794-1-2-E1)
1500 N
Crush resistance (IEC 60794-1-E3)
300 N/cm
Usage characteristics
Operating temperature, range
-40...70 °C
Minimum dynamic operating bending radius
180.0 mm
Minimum static operating bending radius
130 mm
Storage temperature, range
-40...70 °C
Ambient installation temperature, range
0...40 °C